Glow Worm Boiler Fault Code F9

Contents

Important Attempting repairs can be dangerous.

Transcript The interactive transcript could not be loaded. Any ideas. F09 error code Glow Worm Flexicom. Heating is off for 6-8 hours overnight.What else can I do other than keep repressurising it every day?Starting to drive me mental! Check This Out

Re the pump if you remove the large silver screw and insert a small screwdriver you should feel the pump spinning, if not flick it clockwise if stuck it should now It could very well be that the boiler itself requires a service, and the probe needs cleaned or replaced. I ma now thinking f ripping mine out as they are just too expensive to maintain. unicuk 9,840 views 1:32 BOILER KEEPS LOSING PRESSURE - WHY AND HOW TO FIX - Plumbing tips - Duration: 9:13. https://www.glow-worm.co.uk/trade/service/fault-finding-codes/subsites/betacom-a-range-7-232599.en_gb.html

Glow.worm Flexicom Boiler Faults

You may also need to replace the ignition leads, depending on the results you find from the multimeter readings. 4. I pulled the 2 sides of the speed control connectors out a bit more to make better contact. gref333, 31 May 2012 #6 (You must log in or sign up to reply here.) Show Ignored Content Loading...

Keeps reading F9. The box on the wall for the power to the bolier is also showing red for alarm. I have replaced the PCB, the pressure sensor. Glow Worm Ignition Fault Fault find Click here to fix Sanyo products.

Working... Glow Worm Flow Filter First time? Please try again later. read this post here For info, it turned out to be the the expansion vessel, perforated, after all.

The Fix: An engineer will either replace the fan or the PCB. Glow Worm Boiler Fault F1 When servicing a boiler, it's not uncommon for a cable to get caught in the casing when putting back together, and this can cause a short circuit indicating a fault at Glow-worm 77,004 views 5:11 How To Top Up Your Boiler Pressure - Duration: 2:26. The problem we have is that we have to switch on the hot water to get heating, it wont switch over to heating only and wont work off the room thermostat.

Glow Worm Flow Filter

To mend any household, kitchen, or other electrical appliance start here.

Many thanks to the engineer who attended this job. Glow.worm Flexicom Boiler Faults Top LordCross Post subject: Re: Glowworm Flexicom recurring F9 fault on ch,Posted: Mon Nov 12, 2012 6:26 pm Senior Member Joined: Wed Nov 30, 2011 11:58 pmPosts: 1412Hasthanked: Glow Worm Boiler Fault Codes Uploaded on Jan 21, 2011This error code is not in the Installation and service manual...Had to call the manufacture..Thank you for not having premium number for the engineers...thank you glow worm.

The box on the wall is the receiver for the wireless thermostat. http://glitchtest.org/glow-worm/glow-worm-boiler-error-code-f4.html I have also pressed the reset for the LED screen on the boiler. Click here for Hewlett-Packard repair information. The Fix: An engineer will likely either replace the gas valve or the PCB/wiring harness. 5. Water Pressure Sensor Fault, Blocked Flow Filter Or Pump Fault

Im not saying not to use the local emergency plumber stroke gas engineer but what I am saying is to choose the best option and if its the middle of the The is normally about a 50% chance that it may be-able to be fix there and then but if this is not the case, at least there has been a full/partial Decided to replace the water pressure sensor as this was the easiest option. http://glitchtest.org/glow-worm/glow-worm-boiler-fault-code-f11.html Help required to Diagnose LKO, 29 Feb 2016, in forum: Plumbing and Central Heating Replies: 36 Views: 1,568 Agile 16 Mar 2016 Glow Worm Cx381 = F14 fault cycling_blue, 24 Jan

About Press Copyright Creators Advertise Developers +YouTube Terms Privacy Policy & Safety Send feedback Try something new! Glow-worm Water Pressure Sensor Ask Rick Ridley Your Own Question Rick Ridley, UK Heating Engineer Category: UK Plumbing Satisfied Customers: 2708 Experience: 30 Years on the tools, now retired, Ex CORGI 15546140 Type Your UK Remlocplumbing 3,838 views 1:34 How to recharge an expansion vessel in a combi boiler - Duration: 2:41.

Advertisements Important Attempting repairs can be dangerous.

Intermittenly sorts itself out with the pressure reading 1.5 bar then goes back to f9 with a clicking noise I think coming from pcb but not sure. I didnt install the PCB. How to fix it. - Duration: 3:36. Glow Worm Boiler Fault F4 Up next F9 Fault.

Sign in 4 5 Don't like this video? When writing this article, the very last job that was done when checking up a F9 fault on the Glow Worm boiler was diagnosed as changing the pump but at the Even got enough hot water out of to do the washing up! http://glitchtest.org/glow-worm/glow-worm-boiler-fault-f5.html Any thoughts?

I have replaced Customer Question Glow worm flexicom 24cx. Expert: Rick Ridley replied4 years ago. It says pressure sensor faulty, loose wires or trapped, pump seized or faulty. However this does seem like a bit of a design flaw.

I know how stressful it is - I've been helping people in the Edinburgh area deal with faulty boilers for over 20 years, and I've had many a run-in with Glow-worm Add to Want to watch this again later? We depend so much on our boilers day in and day out, so it's easy to forget that they're even there, just doing their jobs - that is, until they break The pump was replace then the hot water started to work again.

DALEYPLUMBINGHEATING 15,042 views 6:18 Glow worm Flexicom - Duration: 1:15. Faulty part was identified..but I found more problems ..I inspect the feed and expansion tank in the loft..like thick black mud..worst F&E tank ever..I will video it next time I go...I DIY Repair (Diaphragm replacement) - Duration: 8:53. Post navigation ← Boiler Checked Cold Feed → Search for: Archive Useful Links Home Plumber Gas Safe Information Questions Blog Emergency Plumber © 2010 - 2016 © All Rights Reserved Contact

Loading... F9 fault Code can be found to be either the pump, PCB, dirty pipes. Loading... I have had leaks, sensor problems and on an on.

Is the boiler going through the correct sequence?